Summary of Contents

Page 1 - OVERVIEW AND SETUP GUIDE

MMAC-M5FNBMULTI-MEDIA ACCESS CENTEROVERVIEW AND SETUP GUIDE CABLETRON SYSTEMS, P.O. Box 5005, Rochester, N.H. 03867-0505

Page 2

INTRODUCTION Page 1-5supply requires AC power cycling (turn power switch off, then on again) to recover. A FAULT LED on the power supply module indic

Page 3

INTRODUCTION Page 1-6If a redundant power supply is not desired, a fifth MIM can be installed in the second power supply module slot. Note: The power

Page 4 - VCCI NOTICE

INTRODUCTION Page 1-7 Rack Mountable Chassis The MMAC-M5FNB chassis can be mounted into a standard 19" (48.26 cm) equipment rack. Separate rack

Page 5 - CONTENTS

INSTALLATION REQUIREMENTS AND SPECIFICATIONS Page 2-1 CHAPTER 2INSTALLATION REQUIREMENTS AND SPECIFICATIONS This chapter describes the following:• Si

Page 6 - INTRODUCTION

INSTALLATION REQUIREMENTS AND SPECIFICATIONS Page 2-2• A USA standard 3 prong power receptacle must be located within 2.13 m (7 ft.) of the site.• Th

Page 7

INSTALLATION REQUIREMENTS AND SPECIFICATIONS Page 2-3 PHYSICAL M5FNB Dimensions: 14.8" high x 17" wide x 14.8" long (37.6 cm high x 43

Page 8

INSTALLATION REQUIREMENTS AND SPECIFICATIONS Page 2-4 Note: The maximum power out of each M5PSM power supply will not exceed 300 watts. This unit is

Page 9

INSTALLATION REQUIREMENTS AND SPECIFICATIONS Page 2-5Figure 2-1. The MMAC-M5PSM LEDs OK When lit, this green LED indicates that the(Power Supply) pow

Page 10

INSTALLATION REQUIREMENTS AND SPECIFICATIONSPage 2-6current condition has been corrected, the power supply requires AC power cycling (turn the power s

Page 11

INSTALLATION REQUIREMENTS AND SPECIFICATIONSPage 2-7SAFETYDesigned in accordance with UL1950, CSA C22.2 No. 950, IEC950, and EN60950. Meets the EMI re

Page 12

NOTICE i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior

Page 13 - AND SPECIFICATIONS

MMAC-M5FNB SETUPPage 3-1CHAPTER 3MMAC-M5FNB SETUPThis chapter contains instructions to help you set up Cabletron Systems’ MMAC-M5FNB. You will not nee

Page 14

MMAC-M5FNB SETUPPage 3-23.2 SETTING UP THE MMAC-M5FNBThe following sections list the steps necessary to set up your MMAC-M5FNB, including installing t

Page 15

MMAC-M5FNB SETUPPage 3-3Figure 3-1. Installing the M5FNB into a Rack3. Insert the screws through the holes on the mounting bracket and into the screw

Page 16

MMAC-M5FNB SETUPPage 3-47. Align the slots on each mounting bracket with the desired holes on the equipment rack.8. Insert a bolt (item 5) through the

Page 17 - 220-250V ~ 3A

MMAC-M5FNB SETUPPage 3-5Figure 3-2. Cable Tie Tray Installation3.2.3 Inserting the Fan TrayThe MMAC-M5FNB is equipped with a removable fan tray that a

Page 18

MMAC-M5FNB SETUPPage 3-64. When the MMAC-M5FNB is ready to be turned on, observe the LED on the front of the fan tray. This LED should be red for a mo

Page 19

MMAC-M5FNB SETUPPage 3-7MMAC-M5PSMs are installed, the load is evenly distributed; if one power supply fails for any reason other than a shorted DC ba

Page 20 - CHAPTER 3

MMAC-M5FNB SETUPPage 3-8Install the M5PSM(s) into your MMAC-M5FNB as follows:1. Unpack the M5PSM by removing it from the shipping box and sliding the

Page 21

MMAC-M5FNB SETUPPage 3-9Figure 3-5. Installing the Power Supply Module(s)5. Tighten the knurled knobs to secure the M5PSM to the MMAC-M5FNB.6. If you

Page 22 - Multi Media Access Center

MMAC-M5FNB SETUPPage 3-10To attach the security bars to the chassis:1. Install all power supplies and MIMs in the M5FNB hub, as desired; be sure to in

Page 23

NOTICE ii FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may no

Page 24

MMAC-M5FNB SETUPPage 3-113.2.6 Powering Up the MMAC-M5FNBPower up the MMAC-M5FNB as follows:1. If the MMAC-M5FNB will not be rack mounted, place it on

Page 25 - Slot guide

NOTICE iii VCCI NOTICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and confo

Page 26

CONTENTS v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual ...1-11.2 Using the

Page 27

INTRODUCTION Page 1-1 CHAPTER 1INTRODUCTION The MMAC-M5FNB™ Multi Media Access Center offers maximum flexibility and convenience in the design and o

Page 28

INTRODUCTION Page 1-2 1.2 USING THE MMAC-M5FNB MANUAL SET Other manuals have been developed for the Repeater/Management modules and for each MIM that

Page 29 - TRMIM-4A

INTRODUCTION Page 1-3By Internet mail: [email protected] FAX: (603) 337-3075By BBS: (603) 335-3358 (4 lines available) 1.4 THE MMAC-M5FNB MULTI MED

Page 30

INTRODUCTION Page 1-4Figure 1-1. MMAC-M5FNB with Optional MIMs 1.5 MMAC-M5FNB FEATURES Universal Power Supply The MMAC-M5FNB power supply senses and

Comments to this Manuals

No comments