7F06-02 FDDI SmartSWITCH ™ Interface ModuleUser’s Guide 9031672-01
1-4INTRODUCTION Token Ring to be used with the 7F06-02 Module. These modules provide the capability to share data without the use of external bridges
INTRODUCTION1-5 1.4 RELATED MANUALS The manuals listed below should be used to supplement the procedures and other technical data provided in this m
2-1 CHAPTER 2NETWORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All
2-2NETWORK REQUIREMENTS Transmitter power parameters are listed in Table 2-2.The link distance is up to 2 kilometers on the multimode fiber-optic cabl
NETWORK REQUIREMENTS2-3 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted Pair (UTP) connection. The FPI
2-4NETWORK REQUIREMENTS 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connec
3-1 CHAPTER 3INSTALLATION/REMOVAL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitc
3-2INSTALLATION/REMOVAL Figure 3-1. Installing an FPIM 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The following procedure detail the installing an
INSTALLATION/REMOVAL3-3 Notes: The left most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module.Before installing the 7F06
3-4INSTALLATION/REMOVAL Note: Before removing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by follo
Noticei NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior n
INSTALLATION/REMOVAL3-5 3.3.3 Installing in the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R Workgroup
3-6INSTALLATION/REMOVAL Figure 3-4. Installing the 7F06-02 Module in the 7C04 Workgroup SmartSwitchFigure 3-5. Installing the 7F06-02 Module in the
INSTALLATION/REMOVAL3-7 3.3.4 Removing from the 7C04 or 7C04-R Workgroup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R Workgrou
3-8INSTALLATION/REMOVAL Figure 3-7. Removing the 7F06-02 Module from the 7C04-R Workgroup SmartSwitchFANSSN4321Ejector TabsScrews
4-1CHAPTER 4TROUBLESHOOTINGThe 7F06-02 Module uses LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW L
4-2TROUBLESHOOTINGTable 4-1 indicates the state of the receive port.Table 4-2 indicates the state of the transmit port.Table 4-1. Port Receive LEDsL
TROUBLESHOOTING4-3Table 4-3 indicates the state of the A/B Link LEDs.Table 4-3. Link LEDsA p S B StateGreen N/A N/A Green Ports Enabled & Active
5-1CHAPTER 5TECHNICAL SPECIFICATIONSThis chapter includes the technical specifications for Cabletron Systems 7F06-02 module. Cabletron Systems reserve
5-2TECHNICAL SPECIFICATIONS5.5 SAFETYIt is the responsibility of the person who sells the system to which the module will be a part to ensure that th
Noticeii FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not
Noticeiii VCCI NOTICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial areas) and confor
v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ...1-11.2 THE 7F06-0
viContents 5.7 PHYSICAL ...5-25.7.1 Dimensions ...
1-1 CHAPTER 1INTRODUCTION Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User’s Guide . This guide is a simple reference fo
1-2INTRODUCTION 1.2 THE 7F06-02 MODULE The 7F06-02 Module provides two Fiber Optic ports via front panel FPIM modules. 1.2.1 Cable Type and FPIMs T
INTRODUCTION1-3 Figure 1-1. 7F06-02 Module 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7F0