Cabletron Systems 7H02-06 User's Guide

Browse online or download User's Guide for Network switches Cabletron Systems 7H02-06. Cabletron Systems 7H02-06 User`s guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1

7H02-06 Fast Ethernet SmartSWITCH ™ Interface Module User’s Guide 9031924

Page 2

1-2Introduction 1.2 THE 7H02-06 MODULE The 7H02-06 Module provides six Fast Ethernet ports via 5 RJ45 connectors and one FEPIM. The 7H02-06 Module c

Page 3

Introduction1-3 Figure 1-1. 7H02-06 Module 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7H0

Page 4 - DOC NOTICE

1-4Introduction Ring to be used with the 7H02-06 Module. These modules provide the capability to share data without the use of external bridges or ro

Page 5 - VCCI NOTICE

Introduction1-5 1.3.2 FEPIMs The front panel connections are standard Cabletron FEPIMs. Currently, the 7H02-06 supports the following two FEPIMs: •

Page 6 - AND DISCLAIMER OF LIABILITY

1-6Introduction 1.4 RELATED MANUALS The manuals listed below should be used to supplement the procedures and other technical data provided in this m

Page 7 - CONTENTS

2-1 CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7H02-06 Module, review the network requirements outlined in this chapter. All

Page 8

2-2Network Requirements Transmitter power parameters are listed in Table 2-2.The link distance is up to 2 kilometers on the multimode fiber-optic cabl

Page 9 - 1.1 USING THIS MANUAL

Network Requirements2-3 The link distance is up to 100 meters on unshielded Category 5 twisted pair cable as specified by ANSI TP-PMD. Table 2-3. FE

Page 11 - SmartSwitch

3-1 CHAPTER 3INSTALLATION This chapter contains instructions for unpacking and installing the 7H02-06 Module in the 7C03, 7C04, 7C04-R MMAC SmartSwi

Page 13 - FE-100FXSP

3-2Installation Figure 3-1. Module Bottom View 3. Remove the blank front cover over the FEPIM slot.4. Install the FEPIM as shown in Figure 3-2. Ensu

Page 14 - 1.5 GETTING HELP

Installation3-3 Figure 3-2. Installing an FEPIM 3.3 INSTALLING/REMOVING THE 7H02-06 MODULE The 7H02-06 Module is installed in: the 7C03 MMAC SmartS

Page 15 - Appendix A

3-4Installation 1. Remove the blank panel covering the slot in which the module will be installed. All other slots in the 7C03 must remain covered t

Page 16 - Network Requirements

Installation3-5 3.3.2 Removing the 7H02-06 Module from a 7C03 MMAC SmartSwitch To remove the 7H02-06 Module from a 7C03 MMAC SmartSwitch, follow the

Page 17

3-6Installation 3.3.3 Installing the 7H02-06 Module in a 7C04 or 7C04-R Chassis To install the 7H02-06 Module in a 7C04 or 7C04-R Chassis, follow th

Page 18

Installation3-7 Figure 3-5. Installing the 7H02-06 Module in the 7C04 Workgroup SmartSwitchFigure 3-6. Installing the 7H02-06 Module in the 7C04-R

Page 19

3-8Installation 3.3.4 Removing the 7H02-06 Module from a 7C04 or 7C04-R Chassis To remove the 7H02-06 Module from a 7C04 or 7C04-R Chassis, follow t

Page 20 - Installation

Installation3-9 Figure 3-8. Removing the 7H02-06 Module from the 7C04-R Workgroup SmartSwitch.XXX -XXX-XXXXXX -XXX-XXX4321ScrewsEjector Tabs

Page 21

3-10Installation

Page 22 - TPRMIM-20 TPRMIM-20

4-1CHAPTER 4TROUBLESHOOTINGThe 7H02-06 Module uses LANVIEW, Cabletron Systems built-in visual diagnostic and status monitoring system. With LANVIEW L

Page 23

Noticei NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior n

Page 24

4-2TroubleshootingTable 4-1 indicates the state of the receive port.Table 4-2 indicates the state of the transmit port.Table 4-1. Port Receive LEDsL

Page 25

5-1CHAPTER 5TECHNICAL SPECIFICATIONSThis chapter includes the technical specifications for Cabletron Systems 7H02-06 module. Cabletron Systems reserve

Page 26 - 7C04-R Chassis

5-2Technical Specifications• VCCI Class I5.5 IMMUNITYThe 7H02-06 Module meets the requirements of EN50082-1 including:• IEC 801-2 ESD• IEC 803-1 radia

Page 27 - Ejector Tabs

Technical Specifications5-35.8.3 EnvironmentalOperating Temperature +5° to +40° C (+41° to +104° F)Storage Temperature -30° to +80° C (-22° to +160° F

Page 28

5-4Technical Specifications

Page 29 - TROUBLESHOOTING

A-1APPENDIX AThe 7H02-06 module uses Fast Ethernet Interface Modules (FEPIMs) to provide front panel cable connections. The FEPIMs are user-installabl

Page 30 - Troubleshooting

A-2Figure A-2. FE-100FXThe transmitter power levels listed in Table A-1 are peak power levels after optical overshoot. A peak power meter must be use

Page 31

Noticeii FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not

Page 32 - Technical Specifications

Noticeiii brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE This equipment is in the 1st Class Category (i

Page 33 - 5.8.3 Environmental

Noticeiv EXCLUSION OF WARRANTYAND DISCLAIMER OF LIABILITY 1. EXCLUSION OF WARRANTY. Except as may be specifically provided by Cabletron in writing, Ca

Page 34

v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ...1-11.2 THE 7H02-0

Page 35 - A.2 FE-100FX

viContents 5.3 SAFETY.......5-15.4 EMI ...

Page 36 - Figure A-2. FE-100FX

1-1 CHAPTER 1INTRODUCTION Welcome to Cabletron Systems 7H02-06 Fast Ethernet SmartSwitch ™ Interface Module Installation Guide. This guide is a sim

Comments to this Manuals