Enterasys Xpedition User Reference Manual 29
Hot Swapping a Secondary Control Module
When you press the Hot Swap button, all the LEDs on the Control Module (including
the Offline LED) are deactivated. Figure 3 shows the location of the Offline LED and
Hot Swap button on a Control Module.
Figure 3. Location of Offline LED and Hot Swap Button on a Control Module
You can also use the system hotswap out command in the CLI to deactivate the Control
Module. For example, to deactivate the secondary Control Module in slot CM/1, enter the
following command in Enable mode:
After you enter this command, the Offline LED on the Control Module lights, and
messages appear on the console indicating the Control Module is inoperative.
Removing the Control Module
To remove a Control Module from the XP:
1. Make sure that none of the LEDs on the Control Module are lit.
2. Loosen the captive screws on each side of the Control Module.
3. Carefully remove the Control Module from its slot in the XP chassis.
Installing a Control Module
To install a new Control Module or line card into the slot:
Note: You can install either a line card or a Control Module in slot CM/1, but you can
install only a Control Module in slot CM.
1. Slide the Control Module or line card all the way into the slot, firmly but gently
pressing it in place to ensure that the pins on the back of the card are completely
seated in the backplane.
Note: Make sure the circuit card (and not the metal plate) is between the card
guides. Check both the upper and lower tracks.
10/100 Mgmt
Console
RST
SYS
OK
ERR DIAG
HBT
Hot
Swap
Online Offline
Hot Swap Button
SSR-CM2 CONTROL MODULE
Offline LED
ssr# system hotswap out slot 1
Page view 48