CHAPTER 2: LOCAL MANAGEMENT
2-20 WPIM-E1 LOCAL MANAGEMENT GUIDE
4. Use the arrow keys to highlight E1 Line Coding. Press the
SPACEBAR to select HDB3 or AMI, then press ENTER.
5. Use the arrow keys to highlight E1 Frame Type. Press the
SPACEBAR to select E1 or E1-CRC, then press ENTER.
6. Use the arrow keys to highlight E1 Tx Clock Source. Press the
SPACEBAR to select Local (no clock source provided by telephone
company) or Loop (clock source provided by telephone company),
then press ENTER.
7. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “Save Done!” appears and Local Management
saves the changes to memory.
8. Access the WAN Interface Configuration screen by using the arrow
keys to highlight the WAN Int Config option and then press ENTER.
The value assigned to the Timeslots is the interface being used
for WAN communication. The available interface range is
displayed on the WAN Physical Configuration screen (see
Figure 2-1). You may insert any of the available interface
numbers into the Timeslots.
In the example shown in Figure 2-1, the interface range for
the MicroMMAC with a WPIM-E1 in slot one of the
BRIM-W6 is 2-33. Although any of these values may be used,
Cabletron Systems recommends using the first available
interface number (in this example interface #2).
The following three steps are based on information supplied
by the service provider. Consult the service provider for the
correct settings.
NOTES
If you are using a Local clock source, set only one end of the
circuit for Local, the other end must be set for Loop.
!
CAUTION
Page view 28