9031445 E9 Anomalies
19
ATM Access Modules (9A128-01, 9A426-01, 9A426-02)
ATM Access Modules
(9A128-01, 9A426-01, 9A426-02)
Corrected Anomalies:
Known Anomalies:
1. You can now access the DevTop view for the 9A426-02 without triggering “Device not
Configured” messages.
2. The Simplified Device view within the DevTop now shows the correct device image.
3. The 9A128-01 model type can now be used to model the ATMClientApp application.
Problem 1: The 9A426-01 module does not allow access to the Device Topology view, and does
not show interfaces in other views. (The 9A426-02, however, does allow access to the
Device Topology view and shows interfaces.)
Solution: This is a firmware problem for the 9A426-01; it will be fixed in a future release.