FRACTIONAL E-1 CONFIGURATION USING PPP
WPIM-E1 LOCAL MANAGEMENT GUIDE 2-17
2.4.2 WPIM-E1 Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Proceed with the following steps to configure the WAN Interface through
Local Management.
1. Set the WAN connection Interface Number by typing the same
number into the Interface Number field that was input into the
Timeslots in the WAN Physical Configuration screen, then press
ENTER. (see NOTE on page 2-16).
2. Unless the user sets the Max Xmit Unit, the WPIM-E1 automatically
sets the Max Xmit Unit to 8191 (default) after the active protocol
(PPP) is selected.
3. If the E1 Line Coding is HDB3 on the previous screen:
a. Use the arrow keys to highlight Line Coding. Press the
SPACEBAR to select None, then press ENTER.
b. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select PPP, then press ENTER.
c. Use the arrow keys to highlight PPP Type. Press the SPACEBAR
to select BNCP, then press ENTER.
4. If the E1 Line Coding is AMI on the previous screen:
a. Use the arrow keys to highlight Line Coding. Press the
SPACEBAR to select INV-HDLC, then press ENTER.
b. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select PPP, then press ENTER.
c. Use the arrow keys to highlight PPP Type. Press the SPACEBAR
to select BNCP, then press ENTER.
5. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message “Save Done!” appears and Local Management
saves the changes to memory.