SPECTRUM Enterprise Manager Cisco StrataCom BPX8600 Series
51 of 105
Endpt Pointer
Pointer to channel Endpoint table. This may not
necessarily have a value. If there is no
corresponding Voice Channel Entry in the
endpoint table, this field would be “0.”
IF
The type of line interface associated with this
channel.
Adaptive Voice
Determines whether the channel is configured for
adaptive voice. This feature must be configured at
both ends of the channel. The adaptive voice
feature must also be equipped at each node
terminating the connection. If the adaptive voice
feature is enabled for a channel connection which
is used for a “c” or “v” connection, VAD is
automatically disabled on that channel when
trunk bandwidth is available, and it is enabled
when trunk bandwidth is needed. By DEFAULT
this is True. This variable is not applicable if the
channel is used for signaling.
Dial Type
Information about the dial type that is used on
the channel. Default is Inband dial type. If type is
user configured, the related objects for which
values need to be provided are: Signalling Delay,
Min Wink, and Playout Delay. If the values for any
of these variables are not provided for user
configured dial type, the current values in the
database shall be retained. Each of the variables
can be set independently. This is true for CDP
and CIP cards. By default every voice connection
is configured with Inband signalling.
Signalling Delay
The signaling delay, in milliseconds (ms), to
assign the user configurable dial type. The value
specified is rounded to the closest multiple of 1.5
ms. The default value for inband is “96” and for
pulse it is “96.” When the dial type is inband or
pulse, the value for this field should not be
provided.
Min Wink
The minimum wink, in milliseconds, to assign to
the user configurable dial type. The value
specified is rounded off to the nearest whole
multiple of 3ms. The default value for inband is
“20” and for pulse it is “20.” When the dial type is
inband or pulse, the value for this field should not
be provided.
Playout Delay
The playout delay, in milliseconds, assigned to
the user configurable dial type. The value
specified is rounded. The default value for inband
is “200” and for pulse it is “200.” When the dial
type is inband or pulse, the value for this field
should not be provided.