Cabletron Systems STHI 44 STHI-44 Specifications Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
SPECTRUM Enterprise Manager Cisco StrataCom BPX8600 Series
68 of 105
Sec In Services
The number of seconds in which a connection is
in service. A connection is considered to be in
service if its endpoint is not in alarm, the cards
required to support the connection are present,
and the connection is routed.
Congest Minutes
Number of minutes in which 50% or more frames
are tagged FECN (Forward Explicit Congestion
Notification) by the FRP.
Transmit Statistics Table
EndPt Index
The index to the Transmit Statistics Table.
Bytes
The number of frame bytes received from the
Muxbus and transmitted out the frame relay port.
Frames
The number of frames transmitted out the frame
relay port.
Packets
The number of packets transmitted to the
Muxbus by the local port card.
Frames FECN
The number of frames transmitted out the local
frame relay port with FECN bit set.
Frames BECN
The number of frames transmitted out the local
frame relay port with BECN (Backward Explicit
Congestion Notification) bit set.
Frames DE set
The number of frames transmitted out the local
frame relay port with their DE (Discard Eligible)
bit set. DE bits are only counted by model D
frame relay firmware or later.
Bytes Excess CIR
Frame Relay Endpoint transmitted bytes from
port in excess of CIR.
Frames Excess CIR
Frame Relay Endpoint transmitted frames from
port in excess of CIR.
Discarded Statistics Table
EndPt Index
The index to the Discarded Statistics Table.
Rx Bytes
The number of frame bytes received from the local
frame relay port but discarded before being
transmitted onto the Muxbus, due to the age of
the frame in the IPX system or lack of buffer
space.
Page view 67