Configuration with QuickSET
108 QuickSET Configuration Guide
.
Figure 118 Modify Backup Window
The following are definitions of Dial-Up Settings parameters:
Time to Connect Time to Connect lets you configure the seconds to wait, before attempting to
switch over to the back-up interface. The default is zero. Allowed values are in increments of five
seconds, to a maximum of 10,000 seconds.
Time to Disconnect Time to Disconnect allows you to configure the amount of seconds the
restored primary interface must remain connected, before attempting to switch over from the
back-up interface. The default value is 90 seconds. Allowed values are in increments of five
seconds, up to a maximum of 10,000 seconds. A value of zero is acceptable.
Connect Retries Connect Retries allows you to configure the number of tries to restore the
back-up interface, before giving up. The default value is three. Allowed values are in increments of
one, up to a maximum of 10,000. A value of zero is acceptable.
Retry Interval Retry Interval lets you set up the time between retries (maximum 60 seconds).
Override Primary Connection Override Primary Connection forces the back-up interface to
remain connected, and does not allow the back-up interface to switch back to the primary
interface, even if the primary interface is restored.